canbus: add DSI-fault capture plan to open items
Close propane valve, force a water-heater lockout, capture + diff against healthy baseline. Prime suspects: node 95 b1 (always FF) or node AE page-3 (always 00). Whichever flips becomes the DSI binary_sensor. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -134,6 +134,20 @@ uses to build its UI.
|
|||||||
`6A`/`7F`/`9C` (movement — slide?), find battery SoC / the "4 green lights"
|
`6A`/`7F`/`9C` (movement — slide?), find battery SoC / the "4 green lights"
|
||||||
source.
|
source.
|
||||||
|
|
||||||
|
### TODO: capture the DSI fault (planned 2026-06-12)
|
||||||
|
|
||||||
|
The water-heater DSI fault is almost certainly on the bus but every capture so
|
||||||
|
far is of a *healthy* heater, so the fault encoding is unknown. **Plan:** close
|
||||||
|
the propane tank valve, run the water heater on gas until it locks out (DSI
|
||||||
|
fault light on panel), capture ~20 s with the CANable, then diff against a
|
||||||
|
healthy baseline. Prime suspects (both sit at a constant "all-clear" sentinel
|
||||||
|
in current captures):
|
||||||
|
- **node `95` (heater) page-3 `b1`** — always `0xFF`; expect it to drop/clear a bit on fault.
|
||||||
|
- **node `AE` (type 0x27, ?LP-gas/diagnostics) page-3** — always `0x00`; expect non-zero on fault.
|
||||||
|
|
||||||
|
Whichever flips → becomes a `binary_sensor` in the ESPHome node (the DSI fault
|
||||||
|
the BLE app never exposed). Reset = reopen valve, re-light.
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||