wesandClaude Fable 5 257064289c canbus: document the first-deploy restart trap for rest_command
The alert package looked deployed but the rest_command domain was never
set up — reload_all only reloads already-loaded integrations, so all
four "verified" test fires died with Action-not-found while
check_config said valid. Needs one full core restart on first deploy;
header now says so and gives the verification command.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-06-12 16:14:15 -04:00

67 lines
2.7 KiB
YAML

# Water-heater DSI fault → Discord ping in the server-alerts channel.
#
# The CAN node decodes the heater's DSI lockout (node 95 page-3 b0 bit5 —
# see canbus/README.md); when the burner fails to light (usually an empty
# propane tank) the module latches the fault and this fires the webhook.
#
# Deploy to Pi: /config/packages/dsi_fault_alert.yaml
# Repo copy: canbus/ha/dsi_fault_alert.yaml
#
# ⚠️ FIRST DEPLOY NEEDS A FULL CORE RESTART. reload_all only re-reads config
# for integrations that are already set up; rest_command was a brand-new domain
# on this instance, so until the restart the service didn't exist and every
# automation fire died with "Action rest_command.discord_server_alerts not
# found" — while check_config said valid. Verify with:
# curl .../api/services | jq '[.[].domain] | index("rest_command")'
# Secret: discord_server_alerts_webhook in the Pi's /config/secrets.yaml
# (NOT the Gatus webhook — that one posts somewhere Wes doesn't
# read; this one is confirmed delivering to the alerts channel)
rest_command:
discord_server_alerts:
url: !secret discord_server_alerts_webhook
method: POST
content_type: "application/json; charset=utf-8"
payload: >-
{"username": "Octavia",
"content": {{ message | tojson }},
"allowed_mentions": {"users": ["321798967669030912"]}}
automation:
- id: camper_dsi_fault_discord
alias: "Camper: DSI fault → Discord"
description: >-
10s 'for' debounces a single glitched broadcast frame; a real lockout
is latched by the module so it easily survives the wait.
triggers:
- trigger: state
entity_id: binary_sensor.onecontrol_can_water_heater_dsi_fault
to: "on"
for: "00:00:10"
actions:
- action: rest_command.discord_server_alerts
data:
message: >-
<@321798967669030912> 🔥 **WATER HEATER DSI FAULT** — hey dumbass,
you're out of propane again. (Or the igniter finally died, but let's be honest,
it's the propane.) The heater is in lockout — swap the tank, then
cycle the heater off/on to relight.
mode: single
- id: camper_dsi_fault_cleared_discord
alias: "Camper: DSI fault cleared → Discord"
triggers:
- trigger: state
entity_id: binary_sensor.onecontrol_can_water_heater_dsi_fault
from: "on"
to: "off"
for: "00:00:10"
actions:
- action: rest_command.discord_server_alerts
data:
message: >-
✅ DSI fault cleared — the water heater is lighting again. Crisis
averted. Try to remember this feeling next time you eyeball the
tank gauge and say "eh, it's fine."
mode: single