WesandClaude Sonnet 4.5 27afedb32e Complete rewrite: SnapRAID SMART logger with BackBlaze algorithm
Fetches SMART data from Scrutiny's InfluxDB and calculates failure
probabilities using the exact BackBlaze tables from SnapRAID source.

Key features:
- Calculates both v12 (with attr 193) and v13 (without attr 193) algorithms
- v12 matches SnapRAID pre-v13.0 (includes Load Cycle Count)
- v13 matches modern SnapRAID v13.0+ (excludes Load Cycle Count)
- Stores both values for trending and comparison
- Correctly applies bit masks (16-bit for 187/188, 32-bit for others)
- Annualizes monthly rates and applies Poisson distribution
- Logs to PostgreSQL with device metadata

Solved the mystery: SnapRAID v12 uses attribute 193 which was removed
in v13.0. Load cycle count has massive impact on failure predictions
for some drives (80% vs 4% difference).

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2025-12-07 06:55:39 -05:00

73 lines
2.1 KiB
SQL

-- Migration: Add v13.0 failure probability column
-- Adds a second failure probability column for the modern algorithm (without attr 193)
-- Add new column for v13.0+ algorithm (without attribute 193)
ALTER TABLE smart_metrics
ADD COLUMN IF NOT EXISTS failure_probability_v13_pct DECIMAL(5, 2);
-- Rename existing column to clarify it includes attribute 193 (pre-v13.0)
ALTER TABLE smart_metrics
RENAME COLUMN failure_probability_pct TO failure_probability_v12_pct;
-- Update views to include both columns
DROP VIEW IF EXISTS smart_latest CASCADE;
CREATE VIEW smart_latest AS
SELECT
m.id,
m.timestamp,
m.device_wwn,
d.device_path,
d.serial_number,
d.model,
d.manufacturer,
d.capacity_bytes,
d.size_tb,
d.disk_role,
m.temperature_celsius,
m.power_on_days,
m.error_count,
m.failure_probability_v12_pct, -- With attr 193 (matches your current SnapRAID)
m.failure_probability_v13_pct, -- Without attr 193 (modern SnapRAID v13.0+)
m.smart_attributes
FROM smart_metrics m
INNER JOIN devices d ON m.device_wwn = d.device_wwn
WHERE m.timestamp = (
SELECT MAX(m2.timestamp)
FROM smart_metrics m2
WHERE m2.device_wwn = m.device_wwn
);
DROP VIEW IF EXISTS smart_high_risk;
CREATE VIEW smart_high_risk AS
SELECT *
FROM smart_latest
WHERE failure_probability_v12_pct > 50 -- Using v12 since that matches your SnapRAID
ORDER BY failure_probability_v12_pct DESC;
DROP VIEW IF EXISTS smart_summary;
CREATE VIEW smart_summary AS
SELECT
device_path,
serial_number,
temperature_celsius,
power_on_days,
error_count,
failure_probability_v12_pct, -- With attr 193
failure_probability_v13_pct, -- Without attr 193
size_tb,
disk_role
FROM smart_latest
ORDER BY
CASE disk_role
WHEN 'parity' THEN 1
WHEN '2-parity' THEN 2
ELSE 3
END,
device_path;
COMMENT ON COLUMN smart_metrics.failure_probability_v12_pct IS
'Failure probability using SnapRAID <v13.0 algorithm (includes attribute 193 Load Cycle Count)';
COMMENT ON COLUMN smart_metrics.failure_probability_v13_pct IS
'Failure probability using SnapRAID v13.0+ algorithm (excludes attribute 193)';